Outdoor AC Boundary Vacuum Load Switch

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Beijing
Validity to: Long-term effective
Last update: 2017-12-20 21:22
Browse the number: 489
inquiry
Company Profile
 
 
Product details

outdoor AC boundary vacuum load switch

 FZW28-12F ( FFK ) type user dividing vacuum load switch ( referred to as the demarcation switch ) used in outdoor column installed occasions, has manual and electric operation function. The switch body is introduced by Toshiba Co of Japan VSP5-12 technology ,the switch is a maintenance-free load switch . Vacuum interrupter and SF6 gas on ground and inter phase insulating medium.

 This product conforms to GB3804 AC high voltage load switch: " GBT11022 " and " high voltage switchgear and control gear standards common technical requirements " .

 FZW28-12F type dividing vacuum load switch ( FZW28-12 switch and FDR-01 controller ) with fault detection function, protection and control functions and communication functions, installed in the 10kV overhead transmission line, can realize the automatic removal of single-phase grounding fault and automatic isolation of inter phase short circuit fault . Mounting points for 10kV distribution line user line responsibility demarcation point, also can be applied to meet the requirements of the branch line junction.

No.

Name

Date

1

Method of operation

Manual or automatic (electromagnetic)

2

Rated value

Rated voltage

12kV

Rated current

630A

Rated short-time withstand current(4S)

12.5     16     20

Rated  closing short-circuit current(peak)

31.5     40     50

Rated frequency

50Hz

Operating voltage

AC220V(80%~110~)

3

Power frequency withstand voltage(1min)

On the ground

42kV

Alternate with

42kV

Fracture

48kV

Two of

2kV

4

Impulse withstand voltage(peak)

On the ground

75kV

Alternate with

75kV

Fracture

84kV

5

Net weight


185kg

6

SF6 gas rated pressure


0 psig concentration was above 93%

7

Operationg handle power determination


100~400N

8

Main loop resistance


≤ 500 μ Ω

9

(one)closing operation

184~220V

1 time off 120~180 ms(220V)
400 ms the following(184V)
2 bounce time is not over 10ms
3 absorb and current (peak) and A following
4 maintain current is not more than 0.45A

The minimum switching voltage

120~160V

(two) tripping operation

184~220V

1 time gate The following 1.5s
2 different period of time   under 30ms

Minimum maintain suck and voltage

65~85V

10

Isolating fracture and the vacuum arc-extinguishing chamber and operation time difference

10±2 ms

11

Tightness test (leak)

0.2 Mpa gauge without gas leakAge

12

Vacuum interrupters contact distance

7~9 mm

13

Vacuum interrupters contact distance

3~3.5 mm

14

Isolating distance

25~30 mm

15

Isolating distance

6~13 mm